Print

Ophthalmology. 2005 Apr;112(4):645-9.  

Mirshahi A, Kohnen T.  Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany.  

PURPOSE: To study the effect of microkeratome suction on ocular structures during LASIK. DESIGN: Observational, prospective case series.

 

PARTICIPANTS: Twenty-one eyes of 11 patients with myopia or astigmatic myopia (8 females, 3 males) were included. The mean patient age was 36.3 years (median, 37 years; range, 24-48 years), and the mean spherical equivalent was -5.03 diopters (D) (median, -4.63 D; range, -2.38 to -8.38 D).

 

METHODS: We performed preoperative and intraoperative A-scan ultrasonography during application of suction using the Hansatome microkeratome (Bausch & Lomb Surgical, Munich, Germany) to create corneal flaps during LASIK. We also performed preoperative and postoperative B-scan ultrasonography of the posterior ocular segment with special attention to the presence and size of posterior vitreous detachment (PVD).

 

MAIN OUTCOME MEASURES: We measured changes in the axial length, anterior chamber depth, lens thickness, and vitreous distance (distance from the posterior lens capsule to the posterior pole) during application of the microkeratome suction ring and recorded new occurrences of or increases in the size of the PVD after surgery.

 

RESULTS: The lens thickness decreased (mean change, -0.20 mm; P = 0.001; 95% confidence interval [CI], -0.11 to -0.30) in 18 eyes during application of the suction ring. The vitreous distance increased (mean change, 0.20 mm; P = 0.004; 95% CI, 0.08-0.32) in 16 eyes. No statistically significant changes were found in the anterior chamber depth (P = 0.75) or axial length (P = 0.51). After surgery, 3 of 14 eyes (21.4%) experienced PVD that did not have echographic signs of PVD before surgery. Of 7 eyes with preoperative PVD, the PVD enlarged in 1 eye (14.3%).

 

 

CONCLUSIONS: During application of microkeratome suction, the lens thickness decreases, whereas the vitreous distance increases, suggesting anterior traction on the posterior segment. The relationship between the observed PVD and LASIK merits further investigation.